<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Çözümleri arşivleri | Haktan Bozer</title>
	<atom:link href="https://haktanbozer.com.tr/tag/cozumleri/feed/" rel="self" type="application/rss+xml" />
	<link>https://haktanbozer.com.tr/tag/cozumleri/</link>
	<description>Kişisel Site</description>
	<lastBuildDate>Fri, 04 Dec 2020 21:06:00 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>
	<item>
		<title>Demirdöküm Neva Arıza Tanımları Muhtemel Sebep ve Çözümleri</title>
		<link>https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri</link>
					<comments>https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/#respond</comments>
		
		<dc:creator><![CDATA[Haktan Bozer]]></dc:creator>
		<pubDate>Fri, 04 Dec 2020 20:57:02 +0000</pubDate>
				<category><![CDATA[Nedir?]]></category>
		<category><![CDATA[Arıza]]></category>
		<category><![CDATA[Çözümleri]]></category>
		<category><![CDATA[Demirdöküm]]></category>
		<category><![CDATA[Neva]]></category>
		<category><![CDATA[Tanımları]]></category>
		<guid isPermaLink="false">https://haktanbozer.com.tr/?p=2006</guid>

					<description><![CDATA[<p>&#160; Problem &#160; Kriter &#160; Muhtemel Nedeni &#160; Alınacak Tedbirler CİHAZ ÇALIŞMIYOR, ATEŞLEME YAPMIYOR VEYA STAND-BY LAMBASI  YANMIYOR Pompa  ve/veya fan çalışmıyor &#160; Cihaza elektrik gelmiyor. &#160; Şebeke kablosu bağlantıları ve sigortanın sağlamlığı kontrol edilir. &#160; Voltaj 165 Volt&#8217;tan düşük &#160; Regülatör kullanılmalıdır. &#160; Isıtma tesisatında yeterli basınçta su yoktur. &#160; Düşük Basınç sensörü devreyi...<a class="btnReadMore" href="https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/">Okumaya Devam Et</a></p>
<p>The post <a href="https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/">Demirdöküm Neva Arıza Tanımları Muhtemel Sebep ve Çözümleri</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table style="height: 2095px;" width="570">
<tbody>
<tr>
<td width="96">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="72">&nbsp;</p>
<p><strong>Kri</strong><strong>ter</strong></td>
<td width="210">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="12" width="96"><strong>CİHAZ</strong> <strong>ÇALIŞMIYOR,</strong><strong> ATEŞLEME</strong> <strong>YAPMIYOR</strong></p>
<p><strong>VEYA</strong><strong> STAND-BY LAMBASI  YANMIYOR</strong></td>
<td rowspan="8" width="72"><strong>Pompa</strong><strong>  </strong><strong>ve/veya</strong> <strong>fan</strong> <strong>çalışmıyor</strong></td>
<td width="210">&nbsp;</p>
<p><strong>Cihaza</strong><strong> elektrik gelmiyor.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Şebeke</strong><strong> kablosu bağlantıları ve sigortanın sağlamlığı kontrol edilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Voltaj</strong><strong> 165 Volt&#8217;tan düşük</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Regülatör</strong> <strong>kullanılmalıdır.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Isıtma</strong> <strong>tesisatında</strong> <strong>yeterli</strong> <strong>basınçta</strong><strong> su yoktur.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Düşük</strong> <strong>Basınç</strong> <strong>sensörü</strong><strong> devreyi kesmiştir.</strong><strong> Tesisatın su basıncı kontrol edilerek yeterli miktarda su basılır.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Düşük</strong><strong> basınç sensörü</strong> <strong>arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Tesisat</strong><strong> suyu basıncı yeterli durumda iken düşük basınç hatası veriyorsa, düşük basınç sensörü değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Aşırı</strong><strong> ısınma termostatı arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Parça</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Ana</strong><strong> kart arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Parça</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Su</strong><strong> akış sensörü arızalıdır. (Yaz konumunda)</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Sensör</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong> <strong>basıncı</strong> <strong>yetersizdir.</strong><strong> (Yaz konumunda)</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Pislik</strong><strong> tutucu </strong><strong>tıkanmıştır.</strong> <strong>Temizlenmelidir.</strong></td>
</tr>
<tr>
<td rowspan="4" width="72"><strong>Pompa</strong><strong> ve/veya fan çalışıyor</strong></td>
<td width="210">&nbsp;</p>
<p><strong>Fan</strong><strong> veya fan kablosu arızalıdır</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Fan</strong> <strong>üzerinde</strong> <strong>enerji</strong> <strong>olup</strong> <strong>olmadığı</strong> <strong>ve</strong><strong> çalışması kontrol edilir. Gerekli ise değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Pressostat</strong><strong> arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Pressostat</strong> <strong>değiştirilir.</strong> <strong>Elektrik</strong><strong> bağlantıları kontrol edilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Pressostat</strong> <strong>hortumu</strong> <strong>yerinden</strong><strong> çıkmış ya da kopmuŞtur.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Hortum</strong> <strong>yerine</strong> <strong>takılır/değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Ateşleme</strong> <strong>Elektrodu</strong><strong> Bağlantıları</strong><strong> arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Bağlantılar</strong> <strong>düzeltilir.</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 1624px;" width="570">
<tbody>
<tr>
<td width="67">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="84">&nbsp;</p>
<p><strong>Krit</strong><strong>er</strong></td>
<td width="234">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="7" width="67"><strong>CİHAZ</strong> <strong>ÇALIŞMIYOR</strong> <strong>HERHANG</strong><strong>İ </strong><strong>BİR</strong> <strong>ARIZA</strong> <strong>LAMBASI</strong> <strong>YANIYOR</strong></td>
<td rowspan="4" width="84">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Bu</strong><strong>ji</strong></p>
<p><strong>Ateşl</strong><strong>eme</strong></p>
<p><strong>yapı</strong><strong>yor.</strong></p>
<p><strong>B</strong><strong>rülör</strong></p>
<p><strong>yanmı</strong><strong>yor.</strong></td>
<td width="234">&nbsp;</p>
<p><strong>Cihaza</strong> <strong>yakıt</strong> <strong>girmiyor</strong> <strong>ya</strong> <strong>da</strong> <strong>düşük</strong></p>
<p><strong>basınçta</strong><strong> giriyor.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Cihaza</strong> <strong>gazın</strong> <strong>girip</strong> <strong>girmediği</strong> <strong>ve</strong> <strong>basınçları</strong></p>
<p><strong>kontrol</strong><strong>  </strong><strong>edilir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p><strong>Aşırı</strong> <strong>ısınma</strong> <strong>emniyet</strong> <strong>termostadı</strong> <strong>atmış</strong></p>
<p><strong>veya</strong><strong> arızalıdır.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Emniyet</strong> <strong>termostadı</strong> <strong>ve</strong> <strong>elektrik</strong> <strong>bağlantıları</strong></p>
<p><strong>kontrol</strong> <strong>edilir,</strong> <strong>gerekli</strong> <strong>ise</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p><strong>Ateşleme</strong> <strong>elektrodu</strong> <strong>başka</strong><strong> noktadan</strong></p>
<p><strong>kısa</strong> <strong>devre</strong> <strong>yapıyor</strong> <strong>veya</strong> <strong>brülörden</strong></p>
<p><strong>uza</strong><strong>klaşmıştır.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Kontrol</strong> <strong>edilir</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p><strong>Cihaza</strong> <strong>giren</strong> <strong>gaz</strong> <strong>yakıt</strong> <strong>debisi</strong></p>
<p><strong>yetersizdir.</strong> <strong>Ana</strong><strong> gaz</strong> <strong>Şebekesinde</strong></p>
<p><strong>yüksek</strong> <strong>basınç</strong> <strong>olmasına</strong> <strong>rağmen</strong> <strong>gaz</strong></p>
<p><strong>hattında</strong> <strong>tıkanma</strong> <strong>vardır.</strong></td>
<td width="273">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Gaz</strong> <strong>hattı</strong> <strong>kontrol</strong> <strong>edilir.</strong></td>
</tr>
<tr>
<td rowspan="3" width="84">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Bu</strong><strong>ji</strong><strong> ateşleme yapıyor,</strong></p>
<p><strong>al</strong><strong>ev</strong></p>
<p><strong>o</strong><strong>luşuyor</strong></p>
<p><strong>ve</strong><strong> kısa</strong></p>
<p><strong>s</strong><strong>üre</strong></p>
<p><strong>son</strong><strong>ra</strong></p>
<p><strong>sönü</strong><strong>yor.</strong></td>
<td width="234">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>İyonizasyon</strong> <strong>Elektrodunda</strong> <strong>veya</strong></p>
<p><strong>kablosunda</strong> <strong>arıza</strong> <strong>vardır.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Elektrodun</strong> <strong>alevi</strong> <strong>görebilecek</strong> <strong>pozisyonda</strong><strong> olduğu, kabloda kopma veya bağlantılarında</strong></p>
<p><strong>temassızlık</strong> <strong>olup</strong> <strong>olmadığı</strong> <strong>kontrol</strong> <strong>edilir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong> <strong>debisi</strong> <strong>yetersizdir.</strong> <strong>(Yaz</strong></p>
<p><strong>konum</strong><strong>unda)</strong></td>
<td width="273">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Pislik</strong><strong> tutucu tıkanmıştır. Temizlenmelidir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Pompa</strong> <strong>arızalı</strong> <strong>veya</strong> <strong>tesisatta</strong> <strong>tıkanma</strong><strong> var.</strong></td>
<td width="273">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Tesisattaki</strong> <strong>pislik</strong> <strong>tutucu</strong> <strong>v.b.</strong> <strong>parçalar</strong> <strong>kontrol</strong></p>
<p><strong>edilip</strong> <strong>temizlenir.</strong> <strong>Pompa</strong> <strong>kontrol</strong> <strong>edilir</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 1973px;" width="570">
<tbody>
<tr>
<td width="144">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="3" width="144">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>CİHAZ</strong> <strong>ÇALIŞMIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Anakart</strong><strong> sigortası atmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Sigorta</strong><strong> değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Anakart</strong> <strong>arızalıdır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Anakart</strong> <strong>arızası</strong><strong> kontrol</strong> <strong>edilir/değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Kablolarda</strong><strong> arıza vardır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kablolar</strong><strong> kontrol edilir.</strong></td>
</tr>
<tr>
<td rowspan="4" width="144">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>YETERLİ </strong><strong>SICAKLIKTA</strong><strong> SU ALINAMIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Su</strong><strong> debisi çok fazla.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kullanım</strong><strong>   </strong><strong>suyu</strong><strong>   </strong><strong>debisinin</strong><strong>   </strong><strong>azaltılması</strong><strong>   </strong><strong>tavsiye</strong><strong> edilir. Debi limitörü kontrol edilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Gaz</strong> <strong>giriş basıncı</strong><strong> yetersiz.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Gaz</strong><strong> girişi kontrol edilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Primer</strong> <strong>ya</strong> <strong>da</strong> <strong>sekonder</strong> <strong>eşanjörde</strong><strong> kireç birikmiŞtir.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Eşanjörün</strong> <strong>kireci</strong> <strong>kimyasal</strong> <strong>maddelerle</strong> <strong>temizlenir</strong><strong> ya da değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Üç</strong><strong> yollu vana arızalanmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong><strong> alınırken</strong><strong> ısıtma</strong><strong> tesisatının </strong><strong>ısınıp</strong><strong> ısınmadığı kontrol edilir.</strong></td>
</tr>
<tr>
<td rowspan="2" width="144">&nbsp;</p>
<p><strong>KULLANIM</strong> <strong>SUYU</strong> <strong>HİÇ</strong><strong> ISINMIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Yeterli</strong><strong> debide su alınmamaktadır. Su basıncı düşüktür.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Yaz</strong><strong> konumunda iken su çekilince cihazın çalışıp çalışmadığı  kontrol  edilir. Çalışmıyorsa  Şebeke basıncı ve su akış sensörü kontrol edilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Üç</strong><strong> yollu vana arızalanmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong> <strong>alınırken</strong> <strong>(yaz</strong> <strong>konumunda)</strong> <strong>ısıtma</strong><strong> tesisatının ısınıp ısınmadığı kontrol edilir.</strong></td>
</tr>
<tr>
<td rowspan="4" width="144">&nbsp;</p>
<p><strong>CİHAZ</strong> <strong>ÇOK</strong> <strong>ÇABUK</strong><strong> DEVREYE GİRİP ÇIKIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Tesisatta</strong><strong> hava vardır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Tesisatın</strong> <strong>havası</strong> <strong>alınır.</strong> <strong>Otomatik</strong> <strong>purjörün</strong> <strong>arızalı</strong><strong> olup olmadığı kontrol edilir. Tapası gevşetilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Tesisat</strong> <strong>sisteminde</strong> <strong>tıkanma</strong><strong> vardır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Pislik</strong> <strong>tutucu</strong><strong> v.b. parçaların tıkalı olup olmadığı</strong><strong> kontrol edilir ve temizlenir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Pompa</strong> <strong>arızalıdır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Pompa</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Evin</strong><strong> ısıl kaybı azdır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Evin</strong> <strong>ısıl</strong> <strong>kaybına</strong> <strong>uygun</strong> <strong>Şekilde</strong> <strong>gaz</strong> <strong>valfi</strong> <strong>basıncı</strong><strong> daha düşük bir değere ayarlanarak ya da PCB kartı  üzerindeki  3  nolu  tesisat  kapasite  ayar potansiyometresi kısılarak kapasite düşürülür.</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 757px;" width="570">
<tbody>
<tr>
<td width="144">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="5" width="144"><strong>EMNİYET</strong> <strong>VENTİLİ </strong><strong>SU</strong> <strong>KAÇIRIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Tesisat</strong> <strong>suyu</strong> <strong>basıncı</strong> <strong>3</strong> <strong>bar&#8217;ın</strong><strong> üzerindedir.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Basınç</strong> <strong>düşürülür.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Genleşme</strong><strong> tankı havası azalmış veya membran patlamıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Tankın</strong><strong> arızası giderilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Emniyet</strong> <strong>ventili</strong> <strong>arızalanmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Emn</strong><strong>iyet</strong><strong> ventili değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Tesisat</strong> <strong>suyu</strong> <strong>hacmi</strong> <strong>150</strong> <strong>lt&#8217;den</strong><strong> fazladır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Sisteme</strong> <strong>ek</strong> <strong>olarak</strong> <strong>genleşme</strong> <strong>tankı</strong> <strong>ilave</strong><strong> edilmelidir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Manometre</strong> <strong>göstergesi</strong> <strong>arızalıdır.</strong><strong> Sistemde fazla basınç varken düşük göstermektedir.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Manometre</strong> <strong>değiştirilir.</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/">Demirdöküm Neva Arıza Tanımları Muhtemel Sebep ve Çözümleri</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>