<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Demirdöküm arşivleri | Haktan Bozer</title>
	<atom:link href="https://haktanbozer.com.tr/tag/demirdokum/feed/" rel="self" type="application/rss+xml" />
	<link>https://haktanbozer.com.tr/tag/demirdokum/</link>
	<description>Kişisel Site</description>
	<lastBuildDate>Sun, 13 Dec 2020 22:01:11 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.1</generator>
	<item>
		<title>Demirdöküm Neva Kullanma ve Montaj Kılavuzu</title>
		<link>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-kullanma-ve-montaj-kilavuzu/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=demirdokum-neva-kullanma-ve-montaj-kilavuzu</link>
					<comments>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-kullanma-ve-montaj-kilavuzu/#respond</comments>
		
		<dc:creator><![CDATA[Haktan Bozer]]></dc:creator>
		<pubDate>Sun, 13 Dec 2020 22:01:11 +0000</pubDate>
				<category><![CDATA[İndirmeler]]></category>
		<category><![CDATA[Demirdöküm]]></category>
		<category><![CDATA[Kılavuzu]]></category>
		<category><![CDATA[Kullanım]]></category>
		<category><![CDATA[Montaj]]></category>
		<category><![CDATA[Neva]]></category>
		<guid isPermaLink="false">https://haktanbozer.com.tr/?p=2053</guid>

					<description><![CDATA[<p>Demirdöküm markasının Neva modelli kombisinin kullanma ve montaj kılavuzuna buradan erişebilirsiniz.</p>
<p>The post <a href="https://haktanbozer.com.tr/indirmeler/demirdokum-neva-kullanma-ve-montaj-kilavuzu/">Demirdöküm Neva Kullanma ve Montaj Kılavuzu</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h4>Demirdöküm markasının Neva modelli kombisinin kullanma ve montaj kılavuzuna <a href="https://kombikullanmakilavuzu.files.wordpress.com/2013/01/neva-kullanc4b1m-kc4b1lavuzu.pdf" target="_blank" rel="noopener">buradan</a> erişebilirsiniz.</h4>
<p>The post <a href="https://haktanbozer.com.tr/indirmeler/demirdokum-neva-kullanma-ve-montaj-kilavuzu/">Demirdöküm Neva Kullanma ve Montaj Kılavuzu</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-kullanma-ve-montaj-kilavuzu/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Demirdöküm Neva Arıza Tanımları Muhtemel Sebep ve Çözümleri</title>
		<link>https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri</link>
					<comments>https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/#respond</comments>
		
		<dc:creator><![CDATA[Haktan Bozer]]></dc:creator>
		<pubDate>Fri, 04 Dec 2020 20:57:02 +0000</pubDate>
				<category><![CDATA[Nedir?]]></category>
		<category><![CDATA[Arıza]]></category>
		<category><![CDATA[Çözümleri]]></category>
		<category><![CDATA[Demirdöküm]]></category>
		<category><![CDATA[Neva]]></category>
		<category><![CDATA[Tanımları]]></category>
		<guid isPermaLink="false">https://haktanbozer.com.tr/?p=2006</guid>

					<description><![CDATA[<p>&#160; Problem &#160; Kriter &#160; Muhtemel Nedeni &#160; Alınacak Tedbirler CİHAZ ÇALIŞMIYOR, ATEŞLEME YAPMIYOR VEYA STAND-BY LAMBASI  YANMIYOR Pompa  ve/veya fan çalışmıyor &#160; Cihaza elektrik gelmiyor. &#160; Şebeke kablosu bağlantıları ve sigortanın sağlamlığı kontrol edilir. &#160; Voltaj 165 Volt&#8217;tan düşük &#160; Regülatör kullanılmalıdır. &#160; Isıtma tesisatında yeterli basınçta su yoktur. &#160; Düşük Basınç sensörü devreyi...<a class="btnReadMore" href="https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/">Okumaya Devam Et</a></p>
<p>The post <a href="https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/">Demirdöküm Neva Arıza Tanımları Muhtemel Sebep ve Çözümleri</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></description>
										<content:encoded><![CDATA[<table style="height: 2095px;" width="570">
<tbody>
<tr>
<td width="96">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="72">&nbsp;</p>
<p><strong>Kri</strong><strong>ter</strong></td>
<td width="210">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="12" width="96"><strong>CİHAZ</strong> <strong>ÇALIŞMIYOR,</strong><strong> ATEŞLEME</strong> <strong>YAPMIYOR</strong></p>
<p><strong>VEYA</strong><strong> STAND-BY LAMBASI  YANMIYOR</strong></td>
<td rowspan="8" width="72"><strong>Pompa</strong><strong>  </strong><strong>ve/veya</strong> <strong>fan</strong> <strong>çalışmıyor</strong></td>
<td width="210">&nbsp;</p>
<p><strong>Cihaza</strong><strong> elektrik gelmiyor.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Şebeke</strong><strong> kablosu bağlantıları ve sigortanın sağlamlığı kontrol edilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Voltaj</strong><strong> 165 Volt&#8217;tan düşük</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Regülatör</strong> <strong>kullanılmalıdır.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Isıtma</strong> <strong>tesisatında</strong> <strong>yeterli</strong> <strong>basınçta</strong><strong> su yoktur.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Düşük</strong> <strong>Basınç</strong> <strong>sensörü</strong><strong> devreyi kesmiştir.</strong><strong> Tesisatın su basıncı kontrol edilerek yeterli miktarda su basılır.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Düşük</strong><strong> basınç sensörü</strong> <strong>arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Tesisat</strong><strong> suyu basıncı yeterli durumda iken düşük basınç hatası veriyorsa, düşük basınç sensörü değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Aşırı</strong><strong> ısınma termostatı arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Parça</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Ana</strong><strong> kart arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Parça</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Su</strong><strong> akış sensörü arızalıdır. (Yaz konumunda)</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Sensör</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong> <strong>basıncı</strong> <strong>yetersizdir.</strong><strong> (Yaz konumunda)</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Pislik</strong><strong> tutucu </strong><strong>tıkanmıştır.</strong> <strong>Temizlenmelidir.</strong></td>
</tr>
<tr>
<td rowspan="4" width="72"><strong>Pompa</strong><strong> ve/veya fan çalışıyor</strong></td>
<td width="210">&nbsp;</p>
<p><strong>Fan</strong><strong> veya fan kablosu arızalıdır</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Fan</strong> <strong>üzerinde</strong> <strong>enerji</strong> <strong>olup</strong> <strong>olmadığı</strong> <strong>ve</strong><strong> çalışması kontrol edilir. Gerekli ise değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Pressostat</strong><strong> arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Pressostat</strong> <strong>değiştirilir.</strong> <strong>Elektrik</strong><strong> bağlantıları kontrol edilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Pressostat</strong> <strong>hortumu</strong> <strong>yerinden</strong><strong> çıkmış ya da kopmuŞtur.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Hortum</strong> <strong>yerine</strong> <strong>takılır/değiştirilir.</strong></td>
</tr>
<tr>
<td width="210">&nbsp;</p>
<p><strong>Ateşleme</strong> <strong>Elektrodu</strong><strong> Bağlantıları</strong><strong> arızalıdır.</strong></td>
<td width="271">&nbsp;</p>
<p><strong>Bağlantılar</strong> <strong>düzeltilir.</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 1624px;" width="570">
<tbody>
<tr>
<td width="67">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="84">&nbsp;</p>
<p><strong>Krit</strong><strong>er</strong></td>
<td width="234">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="7" width="67"><strong>CİHAZ</strong> <strong>ÇALIŞMIYOR</strong> <strong>HERHANG</strong><strong>İ </strong><strong>BİR</strong> <strong>ARIZA</strong> <strong>LAMBASI</strong> <strong>YANIYOR</strong></td>
<td rowspan="4" width="84">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Bu</strong><strong>ji</strong></p>
<p><strong>Ateşl</strong><strong>eme</strong></p>
<p><strong>yapı</strong><strong>yor.</strong></p>
<p><strong>B</strong><strong>rülör</strong></p>
<p><strong>yanmı</strong><strong>yor.</strong></td>
<td width="234">&nbsp;</p>
<p><strong>Cihaza</strong> <strong>yakıt</strong> <strong>girmiyor</strong> <strong>ya</strong> <strong>da</strong> <strong>düşük</strong></p>
<p><strong>basınçta</strong><strong> giriyor.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Cihaza</strong> <strong>gazın</strong> <strong>girip</strong> <strong>girmediği</strong> <strong>ve</strong> <strong>basınçları</strong></p>
<p><strong>kontrol</strong><strong>  </strong><strong>edilir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p><strong>Aşırı</strong> <strong>ısınma</strong> <strong>emniyet</strong> <strong>termostadı</strong> <strong>atmış</strong></p>
<p><strong>veya</strong><strong> arızalıdır.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Emniyet</strong> <strong>termostadı</strong> <strong>ve</strong> <strong>elektrik</strong> <strong>bağlantıları</strong></p>
<p><strong>kontrol</strong> <strong>edilir,</strong> <strong>gerekli</strong> <strong>ise</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p><strong>Ateşleme</strong> <strong>elektrodu</strong> <strong>başka</strong><strong> noktadan</strong></p>
<p><strong>kısa</strong> <strong>devre</strong> <strong>yapıyor</strong> <strong>veya</strong> <strong>brülörden</strong></p>
<p><strong>uza</strong><strong>klaşmıştır.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Kontrol</strong> <strong>edilir</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p><strong>Cihaza</strong> <strong>giren</strong> <strong>gaz</strong> <strong>yakıt</strong> <strong>debisi</strong></p>
<p><strong>yetersizdir.</strong> <strong>Ana</strong><strong> gaz</strong> <strong>Şebekesinde</strong></p>
<p><strong>yüksek</strong> <strong>basınç</strong> <strong>olmasına</strong> <strong>rağmen</strong> <strong>gaz</strong></p>
<p><strong>hattında</strong> <strong>tıkanma</strong> <strong>vardır.</strong></td>
<td width="273">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Gaz</strong> <strong>hattı</strong> <strong>kontrol</strong> <strong>edilir.</strong></td>
</tr>
<tr>
<td rowspan="3" width="84">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Bu</strong><strong>ji</strong><strong> ateşleme yapıyor,</strong></p>
<p><strong>al</strong><strong>ev</strong></p>
<p><strong>o</strong><strong>luşuyor</strong></p>
<p><strong>ve</strong><strong> kısa</strong></p>
<p><strong>s</strong><strong>üre</strong></p>
<p><strong>son</strong><strong>ra</strong></p>
<p><strong>sönü</strong><strong>yor.</strong></td>
<td width="234">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>İyonizasyon</strong> <strong>Elektrodunda</strong> <strong>veya</strong></p>
<p><strong>kablosunda</strong> <strong>arıza</strong> <strong>vardır.</strong></td>
<td width="273">&nbsp;</p>
<p><strong>Elektrodun</strong> <strong>alevi</strong> <strong>görebilecek</strong> <strong>pozisyonda</strong><strong> olduğu, kabloda kopma veya bağlantılarında</strong></p>
<p><strong>temassızlık</strong> <strong>olup</strong> <strong>olmadığı</strong> <strong>kontrol</strong> <strong>edilir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong> <strong>debisi</strong> <strong>yetersizdir.</strong> <strong>(Yaz</strong></p>
<p><strong>konum</strong><strong>unda)</strong></td>
<td width="273">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Pislik</strong><strong> tutucu tıkanmıştır. Temizlenmelidir.</strong></td>
</tr>
<tr>
<td width="234">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Pompa</strong> <strong>arızalı</strong> <strong>veya</strong> <strong>tesisatta</strong> <strong>tıkanma</strong><strong> var.</strong></td>
<td width="273">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Tesisattaki</strong> <strong>pislik</strong> <strong>tutucu</strong> <strong>v.b.</strong> <strong>parçalar</strong> <strong>kontrol</strong></p>
<p><strong>edilip</strong> <strong>temizlenir.</strong> <strong>Pompa</strong> <strong>kontrol</strong> <strong>edilir</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 1973px;" width="570">
<tbody>
<tr>
<td width="144">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="3" width="144">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>CİHAZ</strong> <strong>ÇALIŞMIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Anakart</strong><strong> sigortası atmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Sigorta</strong><strong> değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Anakart</strong> <strong>arızalıdır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Anakart</strong> <strong>arızası</strong><strong> kontrol</strong> <strong>edilir/değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Kablolarda</strong><strong> arıza vardır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kablolar</strong><strong> kontrol edilir.</strong></td>
</tr>
<tr>
<td rowspan="4" width="144">&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>YETERLİ </strong><strong>SICAKLIKTA</strong><strong> SU ALINAMIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Su</strong><strong> debisi çok fazla.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kullanım</strong><strong>   </strong><strong>suyu</strong><strong>   </strong><strong>debisinin</strong><strong>   </strong><strong>azaltılması</strong><strong>   </strong><strong>tavsiye</strong><strong> edilir. Debi limitörü kontrol edilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Gaz</strong> <strong>giriş basıncı</strong><strong> yetersiz.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Gaz</strong><strong> girişi kontrol edilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Primer</strong> <strong>ya</strong> <strong>da</strong> <strong>sekonder</strong> <strong>eşanjörde</strong><strong> kireç birikmiŞtir.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Eşanjörün</strong> <strong>kireci</strong> <strong>kimyasal</strong> <strong>maddelerle</strong> <strong>temizlenir</strong><strong> ya da değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Üç</strong><strong> yollu vana arızalanmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong><strong> alınırken</strong><strong> ısıtma</strong><strong> tesisatının </strong><strong>ısınıp</strong><strong> ısınmadığı kontrol edilir.</strong></td>
</tr>
<tr>
<td rowspan="2" width="144">&nbsp;</p>
<p><strong>KULLANIM</strong> <strong>SUYU</strong> <strong>HİÇ</strong><strong> ISINMIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Yeterli</strong><strong> debide su alınmamaktadır. Su basıncı düşüktür.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Yaz</strong><strong> konumunda iken su çekilince cihazın çalışıp çalışmadığı  kontrol  edilir. Çalışmıyorsa  Şebeke basıncı ve su akış sensörü kontrol edilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Üç</strong><strong> yollu vana arızalanmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Kullanım</strong> <strong>suyu</strong> <strong>alınırken</strong> <strong>(yaz</strong> <strong>konumunda)</strong> <strong>ısıtma</strong><strong> tesisatının ısınıp ısınmadığı kontrol edilir.</strong></td>
</tr>
<tr>
<td rowspan="4" width="144">&nbsp;</p>
<p><strong>CİHAZ</strong> <strong>ÇOK</strong> <strong>ÇABUK</strong><strong> DEVREYE GİRİP ÇIKIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Tesisatta</strong><strong> hava vardır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Tesisatın</strong> <strong>havası</strong> <strong>alınır.</strong> <strong>Otomatik</strong> <strong>purjörün</strong> <strong>arızalı</strong><strong> olup olmadığı kontrol edilir. Tapası gevşetilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Tesisat</strong> <strong>sisteminde</strong> <strong>tıkanma</strong><strong> vardır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Pislik</strong> <strong>tutucu</strong><strong> v.b. parçaların tıkalı olup olmadığı</strong><strong> kontrol edilir ve temizlenir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Pompa</strong> <strong>arızalıdır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Pompa</strong> <strong>değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Evin</strong><strong> ısıl kaybı azdır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Evin</strong> <strong>ısıl</strong> <strong>kaybına</strong> <strong>uygun</strong> <strong>Şekilde</strong> <strong>gaz</strong> <strong>valfi</strong> <strong>basıncı</strong><strong> daha düşük bir değere ayarlanarak ya da PCB kartı  üzerindeki  3  nolu  tesisat  kapasite  ayar potansiyometresi kısılarak kapasite düşürülür.</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<table style="height: 757px;" width="570">
<tbody>
<tr>
<td width="144">&nbsp;</p>
<p><strong>Prob</strong><strong>lem</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Muhtemel</strong> <strong>Nedeni</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Alınacak</strong> <strong>Tedbirler</strong></td>
</tr>
<tr>
<td rowspan="5" width="144"><strong>EMNİYET</strong> <strong>VENTİLİ </strong><strong>SU</strong> <strong>KAÇIRIYOR</strong></td>
<td width="204">&nbsp;</p>
<p><strong>Tesisat</strong> <strong>suyu</strong> <strong>basıncı</strong> <strong>3</strong> <strong>bar&#8217;ın</strong><strong> üzerindedir.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Basınç</strong> <strong>düşürülür.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Genleşme</strong><strong> tankı havası azalmış veya membran patlamıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Tankın</strong><strong> arızası giderilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Emniyet</strong> <strong>ventili</strong> <strong>arızalanmıştır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Emn</strong><strong>iyet</strong><strong> ventili değiştirilir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Tesisat</strong> <strong>suyu</strong> <strong>hacmi</strong> <strong>150</strong> <strong>lt&#8217;den</strong><strong> fazladır.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Sisteme</strong> <strong>ek</strong> <strong>olarak</strong> <strong>genleşme</strong> <strong>tankı</strong> <strong>ilave</strong><strong> edilmelidir.</strong></td>
</tr>
<tr>
<td width="204">&nbsp;</p>
<p><strong>Manometre</strong> <strong>göstergesi</strong> <strong>arızalıdır.</strong><strong> Sistemde fazla basınç varken düşük göstermektedir.</strong></td>
<td width="295">&nbsp;</p>
<p><strong>Manometre</strong> <strong>değiştirilir.</strong></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/">Demirdöküm Neva Arıza Tanımları Muhtemel Sebep ve Çözümleri</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://haktanbozer.com.tr/nedir/demirdokum-neva-ariza-tanimlari-muhtemel-sebep-ve-cozumleri/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Demirdöküm Neva Servis Kitapçığı</title>
		<link>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi-2/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=demirdokum-neva-servis-kitapcigi-2</link>
					<comments>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi-2/#respond</comments>
		
		<dc:creator><![CDATA[Haktan Bozer]]></dc:creator>
		<pubDate>Fri, 04 Dec 2020 20:40:16 +0000</pubDate>
				<category><![CDATA[İndirmeler]]></category>
		<category><![CDATA[Demirdöküm]]></category>
		<category><![CDATA[Kitapçığı]]></category>
		<category><![CDATA[Neva]]></category>
		<category><![CDATA[Servis]]></category>
		<guid isPermaLink="false">https://haktanbozer.com.tr/?p=2004</guid>

					<description><![CDATA[<p>Demirdöküm markasının Neva modelli kombisinin servis kitapçığına ihtiyacınız olabilir. Servis kitapçığı sayesinde cihazınız hakkında detaylı olarak teknik bilgi edinebilirsiniz. Servis kitapçığı sayesinde cihazınıza yapılacak teknik işlemlerin nasıl olacağını öğrenebilirsiniz. Servis kitapçığı sayesinde cihazınızın servis menüsü kodlarını öğrenebilirsiniz. &#160; Servis Kitapçığını bu linkten edinebilirsiniz.</p>
<p>The post <a href="https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi-2/">Demirdöküm Neva Servis Kitapçığı</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Demirdöküm</strong> markasının <strong>Neva</strong> modelli kombisinin<strong> servis kitapçı</strong>ğına ihtiyacınız olabilir. <strong>Servis kitapçığı</strong> sayesinde cihazınız hakkında detaylı olarak teknik bilgi edinebilirsiniz. <strong>Servis kitapçığı</strong> sayesinde cihazınıza yapılacak teknik işlemlerin nasıl olacağını öğrenebilirsiniz. <strong>Servis kitapçığı</strong> sayesinde cihazınızın servis menüsü kodlarını öğrenebilirsiniz.</p>
<p>&nbsp;</p>
<h4><strong>Servis Kitapçığı</strong>nı <a href="https://servis.demirdokum.com.tr/Data/DEMSER/Dokuman/EgitimDoc/EGITIM_NEVA_KOMBI_2008_003.pdf" target="_blank" rel="noopener noreferrer">bu linkten</a> edinebilirsiniz.</h4>
<p>The post <a href="https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi-2/">Demirdöküm Neva Servis Kitapçığı</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Demirdöküm Neva Hata Kodları</title>
		<link>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=demirdokum-neva-servis-kitapcigi</link>
					<comments>https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi/#respond</comments>
		
		<dc:creator><![CDATA[Haktan Bozer]]></dc:creator>
		<pubDate>Fri, 04 Dec 2020 20:08:33 +0000</pubDate>
				<category><![CDATA[İndirmeler]]></category>
		<category><![CDATA[Demirdöküm]]></category>
		<category><![CDATA[Hata]]></category>
		<category><![CDATA[Kodları]]></category>
		<category><![CDATA[Neva]]></category>
		<guid isPermaLink="false">https://haktanbozer.com.tr/?p=1996</guid>

					<description><![CDATA[<p>&#160; F01 İkazı &#8211; Aşırı ısınma hatası: Tesisat suyu sıcaklığının 98°C üzerine çıkması durumunda cihaz çalışmayı durdurur ve ekranda RESET sembolü ile F01 hata kodu yanıp sönmeye başlar. Cihazın tekrar devreye girebilmesi için 8 No&#8217;lu tuşa (Resim 26) 1 kere basılmalıdır. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz. F02 İkazı &#8211; Kullanım suyu...<a class="btnReadMore" href="https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi/">Okumaya Devam Et</a></p>
<p>The post <a href="https://haktanbozer.com.tr/indirmeler/demirdokum-neva-servis-kitapcigi/">Demirdöküm Neva Hata Kodları</a> appeared first on <a href="https://haktanbozer.com.tr">Haktan Bozer</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://haktanbozer.com.tr/wp-content/uploads/2020/12/tuslar.jpg"><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-1998" src="https://haktanbozer.com.tr/wp-content/uploads/2020/12/tuslar.jpg" alt="" width="561" height="194" /></a></p>
<p>&nbsp;</p>
<p>F01 İkazı &#8211; Aşırı ısınma hatası: Tesisat suyu sıcaklığının 98°C üzerine çıkması durumunda cihaz çalışmayı durdurur ve ekranda RESET sembolü ile F01 hata kodu yanıp sönmeye başlar. Cihazın tekrar devreye girebilmesi için 8 No&#8217;lu tuşa (Resim 26) 1 kere basılmalıdır. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F02 İkazı &#8211; Kullanım suyu NTC sensör hatası: Kullanım suyu sensöründe hata varsa ekranda F02 kodu yanıp söner. Kullanım suyu; tesisat gidiş-dönüş NTC Sensörleri tarafından kontrol edildiğinden, cihaz ancak tesisat suyunun belirli sıcaklık değerleri arasında çalışabilir. Bu durumda lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F03 İkazı &#8211; Tesisat devresi gidiş NTC sensör hatası: Tesisat suyu sensöründe ya da kablo bağlantılarında hata varsa ekranda F03 okunur. Cihaz kendini emniyete alır. Bu durumda en yakın yetkili servisimize başvurunuz.</p>
<p>F04 İkazı -İyonizasyon hatası: Kombinize giren gazın kesilmesi veya ateşleme başarısızlığı durumunda cihaz kendini emniyete alır, kumanda panelindeki RESET yazısı yanar ve ekranda F04 kodu okunur. Bu durumda reset düğmesine (8 No&#8217;lu tuia) (Resim 26) bir kez basınız, sorun devam ederse en yakın yetkili servisimize başvurunuz.</p>
<p>F05 İkazı &#8211; Hava akış anahtarı (Pressostat) hatası: Kombinize yerleştirilmiş olan hava akış anahtarı (pressostat) sayesinde atık gaz çıkış veya taze hava girişinde herhangi bir problem (geri tepme, tıkanma, vb.) olması durumunda cihazınız kendini emniyete alır ve ekranda F05 kodu okunur. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F06 İkazı &#8211; Tesisat devresi dönüş NTC sensörü: Tesisat devresi dönüş NTC sensöründe yada kablo bağlantılarında hata varsa ekranda bu hata kodu yanar. Bu durumda lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F07 İkazı &#8211; Gaz valfi geri besleme hatası: Gaz valfi sürme devresinde bir hata olması durumunda cihaz çalışmayı durdurur ve ekranda RESET sembolü ile F07 hata kodu yanıp sönmeye başlar. Cihazın tekrar devreye girebilmesi için 8 No&#8217;lu tuşa (Resim 26) 1 kere basılmalıdır. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F08 İkazı &#8211; CH gidiş NTC aşırı ısınma hatası: Tesisat Devresi gidiş NTC sensor sıcaklık ölçümü 95°C ve üzerinde ise ekranda bu hata kodu belirir. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F09 İkazı &#8211; Hava akış anahtarı kısa devre hatası: Cihazın çalışmaya başlaması sırasında hava akış anahtarı kapalı veya anakart ile hava akış anahtarı arasındaki kablolar kısa devre ise bu hata kodu ekranda belirir. Bu durumda lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F10 İkazı &#8211; Tesisat devresi su basıncı hatası: Kombi, su basıncı 0,8 ve 2,5 bar değerleri arasında çalışmaktadır. Bunun dışındaki herhangi bir basınç değerinde kombi F10 arızası vermektedir. Bu durumda, ekrandaki göstergede basınç değeri 1,5 bar değerine getirilmelidir. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F11 ikazı &#8211; Sirkülasyon hatası: Tesisat gidiş ile tesisat dönüş suyu arasındaki sıcaklık farkı 40°C olduğunda bu hata kodu ekranda yanıp sönmeye başlar. Bu durumda tesisat vanalarının açık olduğundan ve radyatör vanalarının kapalı olmadığından emin olunuz. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F12 İkazı &#8211; Düşük voltaj hatası (Voltaj &lt; 165 V): Şebeke gerilimi 165 V&#8217;un altına düştüğünde ekranda F12 sembolü belirir. Şebeke gerilimi 165 Volt&#8217;un üstüne çıktığında ise cihaz çalışmaya başlar. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>F13 İkazı &#8211; Tesisat devresi NTC&#8217;leri ters takılmış / takılmamış hatası: 20 sn, boyunca tesisat dönüş suyu sıcaklığı gidiş suyu sıcaklığından 7°C fazla olursa bu hata kodu ekranda belirir. Kullanım suyu çalışırken bu hata oluşmaz. Sorun devam ederse lütfen en yakın yetkili servisimize başvurunuz.</p>
<p>Not: Ekran üzerinde arıza koduyla beraber Reset yazısı görüldüğünde arızanın giderilmesiyle beraber sistem 8 No&#8217;lu tuşa 1 kere basılarak (Resim 26) resetlenmelidir.</p>